Ipmicfg: Difference between revisions
Jump to navigation
Jump to search
(5 intermediate revisions by the same user not shown) | |||
Line 22: | Line 22: | ||
=== Get BMC and Host MACs === | === Get BMC and Host MACs === | ||
# -summary Displays FW and BIOS information. | |||
<pre> | <pre> | ||
>IPMICFG-Win.exe -summary | >IPMICFG-Win.exe -summary | ||
Line 34: | Line 37: | ||
System LAN1 MAC Address: 3C:EC:EF:C5:23:XX | System LAN1 MAC Address: 3C:EC:EF:C5:23:XX | ||
System LAN2 MAC Address: 3C:EC:EF:C4:53:XX | System LAN2 MAC Address: 3C:EC:EF:C4:53:XX | ||
</pre> | |||
=== IPMI Link Status === | |||
# -linkstatus Shows network link status. | |||
<pre> | |||
>IPMICFG-Win.exe -linkstatus | |||
General | |||
------- | |||
Hostname : | |||
MAC Address : 3C:EC:EF:36:0C:XX | |||
VLAN : OFF | |||
VLAN ID : N/A | |||
LAN Interface : Dedicate | |||
RMCP Port : 623 | |||
Active Interface : Dedicate | |||
Dedicated | |||
--------- | |||
Link : Auto Negotiation | |||
Status : Disconnected | |||
Speed : Unknown | |||
Duplex : Unknown | |||
</pre> | |||
=== Link Options === | |||
# -lani [option] Gets/Sets LAN interface. | |||
<pre> | |||
>IPMICFG-Win.exe -lani | |||
Current LAN interface is [ Dedicated ] | |||
Supported parameter for setting: | |||
0: Dedicated | |||
</pre> | </pre> | ||
Line 46: | Line 85: | ||
BMC cold reset successfully completed! | BMC cold reset successfully completed! | ||
== IPMI BMC Firmware Version == | |||
>ipmicfg -ver | |||
Firmware Version: 01.01.04 | |||
== Fan Speed == | |||
<pre> | |||
>ipmicfg.exe -fan | |||
Current Fan Speed Mode is [ Optimal Mode ] | |||
Supported Fan modes: | |||
0:Standard | |||
1:Full | |||
2:Optimal | |||
4:Heavy IO | |||
</pre> | |||
<pre> | |||
-fan Gets the fan mode. | |||
-fan <mode> Sets the fan mode. | |||
</pre> | |||
== FRU List == | == FRU List == | ||
Get FRU details: (Field Replaceable Unit) | |||
<pre> | <pre> | ||
> IPMICFG-Win.exe -fru list | > IPMICFG-Win.exe -fru list | ||
Line 63: | Line 126: | ||
Product Asset Tag (PAT) = | Product Asset Tag (PAT) = | ||
</pre> | </pre> | ||
Get FRU Detail: | |||
> ipmicfg -fru BM | |||
Supermicro | |||
Set FRU detail: | |||
> ipmicfg -fru BPN X13SAE-F | |||
Board Product Name (BPN) = X13SAE-F | |||
== Users == | == Users == | ||
Line 86: | Line 158: | ||
-user setpwd <user id> Updates a user password. | -user setpwd <user id> Updates a user password. | ||
<password> | <password> | ||
</pre> | |||
== SDR Stats == | |||
<pre> | |||
>IPMICFG-Win.exe -sdr | |||
Status | (#)Sensor | Reading | Low Limit | High Limit | | |||
------ | --------- | ------- | --------- | ---------- | | |||
OK | (4) CPU Temp | 74C/165F | 5C/41F | 100C/212F | | |||
OK | (71) PCH Temp | 50C/122F | 5C/41F | 90C/194F | | |||
OK | (138) System Temp | 29C/84F | 5C/41F | 85C/185F | | |||
OK | (205) Peripheral Temp | 30C/86F | 5C/41F | 85C/185F | | |||
OK | (272) VRM_VCORE Temp | 32C/90F | 5C/41F | 100C/212F | | |||
OK | (339) VRMVIN_AUX Temp | 29C/84F | 5C/41F | 100C/212F | | |||
OK | (406) DIMMAB Temp | 31C/88F | 5C/41F | 85C/185F | | |||
| (473) M2SSD1 Temp | N/A | N/A | N/A | | |||
| (540) M2SSD2 Temp | N/A | N/A | N/A | | |||
| (607) M2SSD3 Temp | N/A | N/A | N/A | | |||
OK | (674) CPU_FAN1 | 2380 RPM | 420 RPM | 35560 RPM | | |||
| (741) CPU_FAN2 | N/A | N/A | N/A | | |||
OK | (808) SYS_FAN1 | 980 RPM | 420 RPM | 35560 RPM | | |||
OK | (875) SYS_FAN2 | 840 RPM | 420 RPM | 35560 RPM | | |||
OK | (942) SYS_FAN3 | 840 RPM | 420 RPM | 35560 RPM | | |||
OK | (1009) 12V | 12.299 V | 10.283 V | 13.307 V | | |||
OK | (1076) 5VCC | 5.083 V | 4.281 V | 5.505 V | | |||
OK | (1143) 3.3VCC | 3.358 V | 2.841 V | 3.663 V | | |||
OK | (1210) VBAT | Battery presence detected | | |||
OK | (1277) VDD_5_DUAL | 5.019 V | 4.261 V | 5.524 V | | |||
OK | (1344) VDD_33_DUAL | 3.332 V | 2.839 V | 3.661 V | | |||
OK | (1411) 1.8V PCH | 1.814 V | 1.645 V | 1.970 V | | |||
OK | (1478) PVNN PCH | 0.842 V | 0.675 V | 0.998 V | | |||
OK | (1545) 1.05V PCH | 1.050 V | 0.893 V | 1.226 V | | |||
OK | (1612) 2.5V BMC | 2.536 V | 2.348 V | 2.653 V | | |||
OK | (1679) 1.8V BMC | 1.812 V | 1.643 V | 1.955 V | | |||
OK | (1746) 1.2V BMC | 1.210 V | 1.043 V | 1.367 V | | |||
OK | (1813) 1.0V BMC | 1.016 V | 0.840 V | 1.163 V | | |||
OK | (1880) VDimmAB | 1.124 V | 0.947 V | 1.280 V | | |||
OK | (1947) P_VCCIN_AUX_CPU | 1.807 V | 1.640 V | 1.964 V | | |||
OK | (2014) 1.05V CPU | 1.039 V | 0.882 V | 1.206 V | | |||
OK | (2081) Chassis Intru | OK | | |||
</pre> | |||
<pre> | |||
-sdr [full] Shows SDR records and readings. | |||
-sdr del <sdr id> Deletes the SDR record. | |||
-sdr ver <v1> <v2> Gets/Sets the SDR version. (<v1> and <v2> are | |||
BCD-format) | |||
</pre> | |||
== SEL Logs == | |||
<pre> | |||
>IPMICFG-Win.exe -sel list | |||
-------------------------------------------------------------------- | |||
Event:1 Time:2022-01-04 10:10:32 Severity:Warning SensorType:AC Power On | |||
| Msg = [PWR-0020] First AC Power on - Assertion | |||
-------------------------------------------------------------------- | |||
Event:2 Time:2022-01-04 10:10:32 Severity:Warning SensorType:AC Power On | |||
| Msg = [PWR-0020] First AC Power on - Assertion | |||
-------------------------------------------------------------------- | |||
Event:3 Time:2024-07-01 18:04:47 Severity:OK SensorType:System NIC | |||
| Msg = [LAN-0005] Dedicated LAN Link Up - Assertion | |||
-------------------------------------------------------------------- | |||
Event:4 Time:2024-03-08 01:58:21 Severity:OK SensorType:System NIC | |||
| Msg = [LAN-0005] Dedicated LAN Link Up - Assertion | |||
-------------------------------------------------------------------- | |||
Event:5 Time:2024-03-08 02:01:05 Severity:Warning SensorType:System NIC | |||
| Msg = [LAN-0006] Dedicated LAN Link Down - Assertion | |||
-------------------------------------------------------------------- | |||
Event:6 Time:2024-03-08 01:58:46 Severity:Warning SensorType:AC Power On | |||
| Msg = [PWR-0020] First AC Power on - Assertion | |||
-------------------------------------------------------------------- | |||
Event:7 Time:2024-03-08 01:58:21 Severity:OK SensorType:System NIC | |||
| Msg = [LAN-0005] Dedicated LAN Link Up - Assertion | |||
-------------------------------------------------------------------- | |||
Event:8 Time:2024-07-10 10:53:54 Severity:Warning SensorType:AC Power On | |||
| Msg = [PWR-0020] First AC Power on - Assertion | |||
-------------------------------------------------------------------- | |||
Event:9 Time:2024-07-10 10:54:42 Severity:OK SensorType:Base OS Boot / Installation Status | |||
| Msg = [SYS-0056] C: Boot Completed - Assertion | |||
-------------------------------------------------------------------- | |||
Event:10 Time:2024-07-10 10:56:08 Severity:Warning SensorType:OS Stop / Shutdown | |||
| Msg = [SYS-0069] OS graceful shutdown - Assertion | |||
-------------------------------------------------------------------- | |||
Event:11 Time:2024-07-10 10:57:08 Severity:OK SensorType:Base OS Boot / Installation Status | |||
| Msg = [SYS-0056] C: Boot Completed - Assertion | |||
-------------------------------------------------------------------- | |||
Event:12 Time:2024-07-16 10:59:58 Severity:Critical SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion | |||
-------------------------------------------------------------------- | |||
Event:13 Time:2024-07-16 10:59:58 Severity:OK SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion | |||
-------------------------------------------------------------------- | |||
Event:14 Time:2024-07-16 11:00:23 Severity:Critical SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion | |||
-------------------------------------------------------------------- | |||
Event:15 Time:2024-07-16 11:00:24 Severity:OK SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion | |||
-------------------------------------------------------------------- | |||
Event:16 Time:2024-07-16 11:00:24 Severity:Critical SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion | |||
-------------------------------------------------------------------- | |||
Event:17 Time:2024-07-16 11:00:25 Severity:OK SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion | |||
-------------------------------------------------------------------- | |||
Event:18 Time:2024-07-16 11:00:26 Severity:Critical SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion | |||
-------------------------------------------------------------------- | |||
Event:19 Time:2024-07-16 11:00:27 Severity:OK SensorType:Temperature | |||
| Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion | |||
-------------------------------------------------------------------- | |||
Event:430 Time:2024-07-31 10:21:54 Severity:Warning SensorType:OS Stop / Shutdown | |||
| Msg = [SYS-0069] OS graceful shutdown - Assertion | |||
-------------------------------------------------------------------- | |||
Event:431 Time:2024-07-31 10:22:57 Severity:OK SensorType:Base OS Boot / Installation Status | |||
| Msg = [SYS-0056] C: Boot Completed - Assertion | |||
-------------------------------------------------------------------- | |||
Event:432 Time:2024-07-31 10:39:13 Severity:Warning SensorType:OS Stop / Shutdown | |||
| Msg = [SYS-0069] OS graceful shutdown - Assertion | |||
-------------------------------------------------------------------- | |||
Event:433 Time:2024-07-31 10:40:13 Severity:OK SensorType:Base OS Boot / Installation Status | |||
| Msg = [SYS-0056] C: Boot Completed - Assertion | |||
-------------------------------------------------------------------- | |||
</pre> | </pre> | ||
Latest revision as of 00:07, 14 August 2024
Supermicro ipmicfg
https://www.supermicro.com/en/support/resources/downloadcenter/smsdownload?category=IPMI
choco
choco install ipmicfg
Get IPMI Configuration
Show IPv4 Address and MAC
-m # Shows IPv4 address and MAC.
Get BMC IP and MAC
>IPMICFG-Win.exe -m IP=0.0.0.0 MAC=3C:EC:EF:36:0C:A5
Get BMC and Host MACs
# -summary Displays FW and BIOS information.
>IPMICFG-Win.exe -summary Summary ------------------------------------------- IPv4 Address : 0.0.0.0 BMC MAC Address : 3C:EC:EF:36:0C:XX Firmware Revision : 01.02.01 Firmware Build Time : 03/08/2024 BIOS Version : 3.1 BIOS Build Time : 12/25/2023 System LAN1 MAC Address: 3C:EC:EF:C5:23:XX System LAN2 MAC Address: 3C:EC:EF:C4:53:XX
IPMI Link Status
# -linkstatus Shows network link status.
>IPMICFG-Win.exe -linkstatus General ------- Hostname : MAC Address : 3C:EC:EF:36:0C:XX VLAN : OFF VLAN ID : N/A LAN Interface : Dedicate RMCP Port : 623 Active Interface : Dedicate Dedicated --------- Link : Auto Negotiation Status : Disconnected Speed : Unknown Duplex : Unknown
Link Options
# -lani [option] Gets/Sets LAN interface.
>IPMICFG-Win.exe -lani Current LAN interface is [ Dedicated ] Supported parameter for setting: 0: Dedicated
Reset BMC Cold
ipmicfg-win.exe -r
-r Performs a BMC cold reset. Detects if a BMC reset was successfully performed on the IPMI device, use -d after -r.
BMC cold reset successfully completed!
IPMI BMC Firmware Version
>ipmicfg -ver Firmware Version: 01.01.04
Fan Speed
>ipmicfg.exe -fan Current Fan Speed Mode is [ Optimal Mode ] Supported Fan modes: 0:Standard 1:Full 2:Optimal 4:Heavy IO
-fan Gets the fan mode. -fan <mode> Sets the fan mode.
FRU List
Get FRU details: (Field Replaceable Unit)
> IPMICFG-Win.exe -fru list Board Mfg. Date/Time(BDT) = 2022/11/21 20:03:00 (D3 CF D7) Board Manufacturer (BM) = Supermicro Board Product Name (BPN) = Board Serial Number (BS) = UM22BS023XXX Board Part Number (BP) = Product Manufacturer (PM) = Product Name (PN) = Product Part/Model Number (PPM) = Product Version (PV) = Product Serial Number (PS) = Product Asset Tag (PAT) =
Get FRU Detail:
> ipmicfg -fru BM Supermicro
Set FRU detail:
> ipmicfg -fru BPN X13SAE-F
Board Product Name (BPN) = X13SAE-F
Users
>IPMICFG-Win.exe -user list Maximum number of Users : 16 Count of currently enabled Users : 1 User ID | User Name | Privilege Level | Enable ------- | --------- | --------------- | ------ 2 | admin | Administrator | Yes
help:
-user list Lists user privileges. -user help Shows a user privilege code. -user add <user id> <name> Adds a user. <password> <privilege> -user del <user id> Deletes users. -user level <user id> Updates user privileges. <privilege> -user setpwd <user id> Updates a user password. <password>
SDR Stats
>IPMICFG-Win.exe -sdr Status | (#)Sensor | Reading | Low Limit | High Limit | ------ | --------- | ------- | --------- | ---------- | OK | (4) CPU Temp | 74C/165F | 5C/41F | 100C/212F | OK | (71) PCH Temp | 50C/122F | 5C/41F | 90C/194F | OK | (138) System Temp | 29C/84F | 5C/41F | 85C/185F | OK | (205) Peripheral Temp | 30C/86F | 5C/41F | 85C/185F | OK | (272) VRM_VCORE Temp | 32C/90F | 5C/41F | 100C/212F | OK | (339) VRMVIN_AUX Temp | 29C/84F | 5C/41F | 100C/212F | OK | (406) DIMMAB Temp | 31C/88F | 5C/41F | 85C/185F | | (473) M2SSD1 Temp | N/A | N/A | N/A | | (540) M2SSD2 Temp | N/A | N/A | N/A | | (607) M2SSD3 Temp | N/A | N/A | N/A | OK | (674) CPU_FAN1 | 2380 RPM | 420 RPM | 35560 RPM | | (741) CPU_FAN2 | N/A | N/A | N/A | OK | (808) SYS_FAN1 | 980 RPM | 420 RPM | 35560 RPM | OK | (875) SYS_FAN2 | 840 RPM | 420 RPM | 35560 RPM | OK | (942) SYS_FAN3 | 840 RPM | 420 RPM | 35560 RPM | OK | (1009) 12V | 12.299 V | 10.283 V | 13.307 V | OK | (1076) 5VCC | 5.083 V | 4.281 V | 5.505 V | OK | (1143) 3.3VCC | 3.358 V | 2.841 V | 3.663 V | OK | (1210) VBAT | Battery presence detected | OK | (1277) VDD_5_DUAL | 5.019 V | 4.261 V | 5.524 V | OK | (1344) VDD_33_DUAL | 3.332 V | 2.839 V | 3.661 V | OK | (1411) 1.8V PCH | 1.814 V | 1.645 V | 1.970 V | OK | (1478) PVNN PCH | 0.842 V | 0.675 V | 0.998 V | OK | (1545) 1.05V PCH | 1.050 V | 0.893 V | 1.226 V | OK | (1612) 2.5V BMC | 2.536 V | 2.348 V | 2.653 V | OK | (1679) 1.8V BMC | 1.812 V | 1.643 V | 1.955 V | OK | (1746) 1.2V BMC | 1.210 V | 1.043 V | 1.367 V | OK | (1813) 1.0V BMC | 1.016 V | 0.840 V | 1.163 V | OK | (1880) VDimmAB | 1.124 V | 0.947 V | 1.280 V | OK | (1947) P_VCCIN_AUX_CPU | 1.807 V | 1.640 V | 1.964 V | OK | (2014) 1.05V CPU | 1.039 V | 0.882 V | 1.206 V | OK | (2081) Chassis Intru | OK |
-sdr [full] Shows SDR records and readings. -sdr del <sdr id> Deletes the SDR record. -sdr ver <v1> <v2> Gets/Sets the SDR version. (<v1> and <v2> are BCD-format)
SEL Logs
>IPMICFG-Win.exe -sel list -------------------------------------------------------------------- Event:1 Time:2022-01-04 10:10:32 Severity:Warning SensorType:AC Power On | Msg = [PWR-0020] First AC Power on - Assertion -------------------------------------------------------------------- Event:2 Time:2022-01-04 10:10:32 Severity:Warning SensorType:AC Power On | Msg = [PWR-0020] First AC Power on - Assertion -------------------------------------------------------------------- Event:3 Time:2024-07-01 18:04:47 Severity:OK SensorType:System NIC | Msg = [LAN-0005] Dedicated LAN Link Up - Assertion -------------------------------------------------------------------- Event:4 Time:2024-03-08 01:58:21 Severity:OK SensorType:System NIC | Msg = [LAN-0005] Dedicated LAN Link Up - Assertion -------------------------------------------------------------------- Event:5 Time:2024-03-08 02:01:05 Severity:Warning SensorType:System NIC | Msg = [LAN-0006] Dedicated LAN Link Down - Assertion -------------------------------------------------------------------- Event:6 Time:2024-03-08 01:58:46 Severity:Warning SensorType:AC Power On | Msg = [PWR-0020] First AC Power on - Assertion -------------------------------------------------------------------- Event:7 Time:2024-03-08 01:58:21 Severity:OK SensorType:System NIC | Msg = [LAN-0005] Dedicated LAN Link Up - Assertion -------------------------------------------------------------------- Event:8 Time:2024-07-10 10:53:54 Severity:Warning SensorType:AC Power On | Msg = [PWR-0020] First AC Power on - Assertion -------------------------------------------------------------------- Event:9 Time:2024-07-10 10:54:42 Severity:OK SensorType:Base OS Boot / Installation Status | Msg = [SYS-0056] C: Boot Completed - Assertion -------------------------------------------------------------------- Event:10 Time:2024-07-10 10:56:08 Severity:Warning SensorType:OS Stop / Shutdown | Msg = [SYS-0069] OS graceful shutdown - Assertion -------------------------------------------------------------------- Event:11 Time:2024-07-10 10:57:08 Severity:OK SensorType:Base OS Boot / Installation Status | Msg = [SYS-0056] C: Boot Completed - Assertion -------------------------------------------------------------------- Event:12 Time:2024-07-16 10:59:58 Severity:Critical SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion -------------------------------------------------------------------- Event:13 Time:2024-07-16 10:59:58 Severity:OK SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion -------------------------------------------------------------------- Event:14 Time:2024-07-16 11:00:23 Severity:Critical SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion -------------------------------------------------------------------- Event:15 Time:2024-07-16 11:00:24 Severity:OK SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion -------------------------------------------------------------------- Event:16 Time:2024-07-16 11:00:24 Severity:Critical SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion -------------------------------------------------------------------- Event:17 Time:2024-07-16 11:00:25 Severity:OK SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion -------------------------------------------------------------------- Event:18 Time:2024-07-16 11:00:26 Severity:Critical SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Assertion -------------------------------------------------------------------- Event:19 Time:2024-07-16 11:00:27 Severity:OK SensorType:Temperature | Msg = [IPMI-1009] CPU Temp, Upper Critical - going high - Deassertion -------------------------------------------------------------------- Event:430 Time:2024-07-31 10:21:54 Severity:Warning SensorType:OS Stop / Shutdown | Msg = [SYS-0069] OS graceful shutdown - Assertion -------------------------------------------------------------------- Event:431 Time:2024-07-31 10:22:57 Severity:OK SensorType:Base OS Boot / Installation Status | Msg = [SYS-0056] C: Boot Completed - Assertion -------------------------------------------------------------------- Event:432 Time:2024-07-31 10:39:13 Severity:Warning SensorType:OS Stop / Shutdown | Msg = [SYS-0069] OS graceful shutdown - Assertion -------------------------------------------------------------------- Event:433 Time:2024-07-31 10:40:13 Severity:OK SensorType:Base OS Boot / Installation Status | Msg = [SYS-0056] C: Boot Completed - Assertion --------------------------------------------------------------------
Help Options
IPMICFG-Win.exe -help IPMICFG Version 1.35.2 (Build 240627) Copyright(c) 2023 Super Micro Computer, Inc. Usage: IPMICFG params (Example: IPMICFG -m 192.168.1.123) -help Display a list of commands -m Shows IPv4 address and MAC. -m <ip> Sets IPv4 address (format: ###.###.###.###). -a <mac> Sets MAC (format: ##:##:##:##:##:##). -k Shows Subnet Mask. -k <mask> Sets Subnet Mask (format: ###.###.###.###). -dhcp Gets the DHCP status. -dhcp on Enables the DHCP. -dhcp off Disables the DHCP. -g Shows a Gateway IP. -g <gateway> Sets a Gateway IP (format: ###.###.###.###). -garp on Enables the Gratuitous ARP. -garp off Disables the Gratuitous ARP. -r Performs a BMC cold reset. Detects if a BMC reset was successfully performed on the IPMI device, use -d after -r. -fd <option> Resets to the factory defaults without preserving configurations. option: 1 | Preserves User configurations option: 2 | Restores to factory default and default password option: 3 | Sets user defaults to ADMIN/ADMIN -fdl Resets IPMI to the factory default. (Clean LAN). -fde Resets IPMI to the factory default. (Clean FRU & LAN). -d Detects if a BMC reset was successfully performed on the IPMI device. Note that this option can be only used after -r, -fd, -fdl or -fde -ver Gets firmware revision. -vlan Gets VLAN status. -vlan on [VLAN tag] Enables the VLAN and sets the VLAN tag. If VLAN tag is not given, it uses the previously saved value. -vlan off Disables the VLAN. -selftest Checks and reports the basic health status of the BMC. -raw Sends a RAW IPMI request and prints a response. Format: NetFn/LUN Cmd [Data1 ... DataN] -fru info Shows information of the FRU inventory area. -fru list Shows all FRU values. -fru cthelp Shows chassis type code. -fru help Shows help of FRU Write. -fru <field> Shows FRU field value. -fru <field> <value> Writes FRU. -fru backup <file> Backs up FRU to a file <Binary format>. -fru restore <file> Restores FRU from a file <Binary format>. -fru tbackup <file> Backs up FRU to a file <Text format>. -fru trestore <file> Restores FRU from a file <Text format>. -fru ver <v1> <v2> Gets/Sets the FRU version. (<v1> and <v2> are BCD-format) -fru dmi <$1> ... <$14> Inputs 14 parameters and writes to FRU Chassis/Board/Product fields. Please use the "-fru dmi" command to view the parameters. -sel info Shows SEL information. -sel list [option] Shows SEL records. -y <n years> | Filter event logs within n years -m <n months> | Filter event logs within n months -d <n days> | Filter event logs within n days -sel del Deletes all SEL records. -sel raw Shows SEL raw data. -sdr [full] Shows SDR records and readings. -sdr del <sdr id> Deletes the SDR record. -sdr ver <v1> <v2> Gets/Sets the SDR version. (<v1> and <v2> are BCD-format) -nm nmsdr Displays NM SDR. -nm seltime Gets SEL time. -nm deviceid Gets the ID of the ME device. -nm reset Reboots ME. -nm reset2default Forces ME to reset to default settings. -nm updatemode Forces ME to enter the update mode. -nm selftest Gets self-test results. -nm listimagesinfo Lists ME information of images. -nm oemgetpower OEM Power command for ME. -nm oemgettemp OEM Temp. command for ME. -nm pstate Gets the maximum allowed CPU P-State. -nm tstate Gets the maximum allowed CPU T-State. -nm cpumemtemp Gets CPU/memory temperature. -nm hostcpudata Gets the host CPU data. -fan Gets the fan mode. -fan <mode> Sets the fan mode. -pminfo [full] Displays PMBus health information of power supply. -psfruinfo Displays FRU health information of power supply. -psbbpinfo Displays status of the backup battery. -autodischarge <module> Sets auto discharge by days. <day> -discharge <module> Manually discharges a battery. -user list Lists user privileges. -user help Shows a user privilege code. -user add <user id> <name> Adds a user. <password> <privilege> -user del <user id> Deletes users. -user level <user id> Updates user privileges. <privilege> -user setpwd <user id> Updates a user password. <password> -conf download <file> Downloads IPMI configuration to a binary file. -conf upload <file> Uploads IPMI configuration from a binary file. <option> option: -p | Bypass warning message -conf tdownload <file> Downloads IPMI configuration to a text file. -conf tupload <file> Uploads IPMI configuration from a text file. <option> option: -p | Bypass warning message -clrint Clears chassis intrusion. -reset <index> Resets system and forces to boot from the selected device. -soft <index> Initiates a soft-shutdown for OS and forces system to boot from the selected device. -ipv6 mode Shows the IPv6 mode. -ipv6 mode <mode> Sets the IPv6 mode. -ipv6 autoconfig Shows IPv6 auto configuration. -ipv6 autoconfig on Enables IPv6 auto configuration. -ipv6 autoconfig off Disables IPv6 auto configuration. -ipv6 list Lists IPv6 static and dynamic addresses. -ipv6 duid Shows IPv6 DUID. -ipv6 dns [ip] Gets/Sets IPv6 DNS server. -ipv6 add <id> <ip> Adds IPv6 static address. <prefix> -ipv6 remove <id> Removes IPv6 static address. -ipv6 route Displays IPv6 static route status. -ipv6 route on Enables IPv6 static route. -ipv6 route off Disables IPv6 static route. -ipv6 route list Lists IPv6 static router information. -ipv6 route <id> <prefix Sets IPv6 static router information. value> <prefix length> <ip> -ipv6 route clear <id> Clears IPv6 static router information. -nvme list Displays the existing NVME SSD list. -nvme info Displays NVME SSD information. -nvme rescan Rescans all devices by in-band. -nvme insert <aoc> <group> Inserts SSD by out-of-band. <slot> -nvme locate <HDD name> Locates SSD. (in-band) -nvme locate <aoc> <group> Locates SSD. (out-of-band) <slot> -nvme stoplocate <HDD Stops locateing SSD. (in-band) name> -nvme stoplocate <aoc> Stops locateing SSD. (out-of-band) <group> <slot> -nvme remove <HDD name> Removes NVME device. (in-band) [option1] [option2] option1: 0 | Do eject after remove (Default) option1: 1 | Do not eject after remove option2:-p | Bypass warning message -nvme remove <aoc> <group> Removes NVME device. (out-of-band) <slot> [option] option: -p | Bypass warning message -nvme smartdata [HDD name] NVME S.M.A.R.T data. -tas info Gets TAS information. -tas pause Pauses a TAS service. -tas resume Resumes a TAS service. -tas refresh Triggers TAS to recollect data. -tas clear Clears collected TAS data in BMC. -tas period <sec> Sets the time length of a TAS update <limit 1 to 60 sec>. -tp info Gets MCU information. -tp info <type> Gets information of MCU type. (type: 1 - 3) -tp nodeid Gets a node ID. -tp systemname [value] Gets/Sets a system name. -tp systempn [value] Gets/Sets a system P/N. -tp systemsn [value] Gets/Sets a system S/N. -tp chassispn [value] Gets/Sets a chassis P/N. -tp chassissn [value] Gets/Sets a chassis S/N. -tp backplanepn [value] Gets/Sets a backplane P/N. -tp backplanesn [value] Gets/Sets a backplane S/N. -tp nodepn [value] Gets/Sets node P/N. -tp nodesn [value] Gets/Sets node S/N. -summary Displays FW and BIOS information. -hostname [value] Gets/Sets a host name. -dcmi cap Lists information of DCMI capabilities. -dcmi power Gets the DCMI power readings. -dcmi ctl [value] Gets/Sets the DCMI management controller ID string. -mel list [option] Shows BMC maintenance event log. -y <n years> | Filter event logs within n years -m <n months> | Filter event logs within n months -d <n days> | Filter event logs within n days -mel download <file> Downloads a BMC maintenance event log to a file. -mel clear [0|1] Clears a BMC maintenance event log. (without/with log, default is 0) -addrptl [option] Gets/Sets IP address protocol. option: 1 | IPv4 option: 2 | IPv6 option: 3 | Dual -lockdown Checks the system's lockdown mode. -lani [option] Gets/Sets LAN interface. -linkstatus Shows network link status.