Line 10: | Line 10: | ||
ipmicfg-win.exe -m | ipmicfg-win.exe -m | ||
== Help Options == | |||
<pre> | |||
IPMICFG Version 1.32.0 (Build 200910) | |||
Copyright(c) 2020 Super Micro Computer, Inc. | |||
Usage: IPMICFG params (Example: IPMICFG -m 192.168.1.123) | |||
-help Display a list of commands | |||
-m Shows IPv4 address and MAC. | |||
-m <ip> Sets IPv4 address (format: ###.###.###.###). | |||
-a <mac> Sets MAC (format: ##:##:##:##:##:##). | |||
-k Shows Subnet Mask. | |||
-k <mask> Sets Subnet Mask (format: ###.###.###.###). | |||
-dhcp Gets the DHCP status. | |||
-dhcp on Enables the DHCP. | |||
-dhcp off Disables the DHCP. | |||
-g Shows a Gateway IP. | |||
-g <gateway> Sets a Gateway IP (format: ###.###.###.###). | |||
-garp on Enables the Gratuitous ARP. | |||
-garp off Disables the Gratuitous ARP. | |||
-r Performs a BMC cold reset. | |||
Detects if a BMC reset was successfully performed | |||
on the IPMI device, use -d after -r. | |||
-fd <option> Resets to the factory defaults without preserving | |||
configurations. | |||
option: 1 | Preserves User configurations | |||
option: 2 | Restores to factory default and | |||
default password | |||
option: 3 | Sets user defaults to ADMIN/ADMIN | |||
-fdl Resets IPMI to the factory default. (Clean LAN). | |||
-fde Resets IPMI to the factory default. (Clean FRU & | |||
LAN). | |||
-d Detects if a BMC reset was successfully performed | |||
on the IPMI device. | |||
Note that this option can be only used after -r, | |||
-fd, -fdl or -fde | |||
-ver Gets firmware revision. | |||
-vlan Gets VLAN status. | |||
-vlan on [VLAN tag] Enables the VLAN and sets the VLAN tag. | |||
If VLAN tag is not given, it uses the previously | |||
saved value. | |||
-vlan off Disables the VLAN. | |||
-selftest Checks and reports the basic health status of the | |||
BMC. | |||
-raw Sends a RAW IPMI request and prints a response. | |||
Format: NetFn/LUN Cmd [Data1 ... DataN] | |||
-fru info Shows information of the FRU inventory area. | |||
-fru list Shows all FRU values. | |||
-fru cthelp Shows chassis type code. | |||
-fru help Shows help of FRU Write. | |||
-fru <field> Shows FRU field value. | |||
-fru <field> <value> Writes FRU. | |||
-fru backup <file> Backs up FRU to a file <Binary format>. | |||
-fru restore <file> Restores FRU from a file <Binary format>. | |||
-fru tbackup <file> Backs up FRU to a file <Text format>. | |||
-fru trestore <file> Restores FRU from a file <Text format>. | |||
-fru ver <v1> <v2> Gets/Sets the FRU version. (<v1> and <v2> are | |||
BCD-format) | |||
-sel info Shows SEL information. | |||
-sel list Shows SEL records. | |||
-sel del Deletes all SEL records. | |||
-sel raw Shows SEL raw data. | |||
-sdr [full] Shows SDR records and readings. | |||
-sdr del <sdr id> Deletes the SDR record. | |||
-sdr ver <v1> <v2> Gets/Sets the SDR version. (<v1> and <v2> are | |||
BCD-format) | |||
-nm nmsdr Displays NM SDR. | |||
-nm seltime Gets SEL time. | |||
-nm deviceid Gets the ID of the ME device. | |||
-nm reset Reboots ME. | |||
-nm reset2default Forces ME to reset to default settings. | |||
-nm updatemode Forces ME to enter the update mode. | |||
-nm selftest Gets self-test results. | |||
-nm listimagesinfo Lists ME information of images. | |||
-nm oemgetpower OEM Power command for ME. | |||
-nm oemgettemp OEM Temp. command for ME. | |||
-nm pstate Gets the maximum allowed CPU P-State. | |||
-nm tstate Gets the maximum allowed CPU T-State. | |||
-nm cpumemtemp Gets CPU/memory temperature. | |||
-nm hostcpudata Gets the host CPU data. | |||
-fan Gets the fan mode. | |||
-fan <mode> Sets the fan mode. | |||
-pminfo [full] Displays PMBus health information of power supply. | |||
-psfruinfo Displays FRU health information of power supply. | |||
-psbbpinfo Displays status of the backup battery. | |||
-autodischarge <module> Sets auto discharge by days. | |||
<day> | |||
-discharge <module> Manually discharges a battery. | |||
-user list Lists user privileges. | |||
-user help Shows a user privilege code. | |||
-user add <user id> <name> Adds a user. | |||
<password> <privilege> | |||
-user del <user id> Deletes users. | |||
-user level <user id> Updates user privileges. | |||
<privilege> | |||
-user setpwd <user id> Updates a user password. | |||
<password> | |||
-conf download <file> Downloads IPMI configuration to a binary file. | |||
-conf upload <file> Uploads IPMI configuration from a binary file. | |||
<option> option: -p | Bypass warning message | |||
-conf tdownload <file> Downloads IPMI configuration to a text file. | |||
-conf tupload <file> Uploads IPMI configuration from a text file. | |||
<option> option: -p | Bypass warning message | |||
-clrint Clears chassis intrusion. | |||
-reset <index> Resets system and forces to boot from the selected | |||
device. | |||
-soft <index> Initiates a soft-shutdown for OS and forces system | |||
to boot from the selected device. | |||
-ipv6 mode Shows the IPv6 mode. | |||
-ipv6 mode <mode> Sets the IPv6 mode. | |||
-ipv6 autoconfig Shows IPv6 auto configuration. | |||
-ipv6 autoconfig on Enables IPv6 auto configuration. | |||
-ipv6 autoconfig off Disables IPv6 auto configuration. | |||
-ipv6 list Lists IPv6 static and dynamic addresses. | |||
-ipv6 duid Shows IPv6 DUID. | |||
-ipv6 dns [ip] Gets/Sets IPv6 DNS server. | |||
-ipv6 add <id> <ip> Adds IPv6 static address. | |||
<prefix> | |||
-ipv6 remove <id> Removes IPv6 static address. | |||
-ipv6 route Displays IPv6 static route. | |||
-ipv6 route on Enables IPv6 static route. | |||
-ipv6 route off Disables IPv6 static route. | |||
-ipv6 route list Lists IPv6 static router information. | |||
-ipv6 route <id> <prefix Sets IPv6 static router information. | |||
value> <prefix length> | |||
<ip> | |||
-ipv6 route clear <id> Clears IPv6 static router information. | |||
-nvme list Displays the existing NVME SSD list. | |||
-nvme info Displays NVME SSD information. | |||
-nvme rescan Rescans all devices by in-band. | |||
-nvme insert <aoc> <group> Inserts SSD by out-of-band. | |||
<slot> | |||
-nvme locate <HDD name> Locates SSD. (in-band) | |||
-nvme locate <aoc> <group> Locates SSD. (out-of-band) | |||
<slot> | |||
-nvme stoplocate <HDD Stops locateing SSD. (in-band) | |||
name> | |||
-nvme stoplocate <aoc> Stops locateing SSD. (out-of-band) | |||
<group> <slot> | |||
-nvme remove <HDD name> Removes NVME device. (in-band) | |||
[option1] [option2] option1: 0 | Do eject after remove (Default) | |||
option1: 1 | Do not eject after remove | |||
option2:-p | Bypass warning message | |||
-nvme remove <aoc> <group> Removes NVME device. (out-of-band) | |||
<slot> [option] option: -p | Bypass warning message | |||
-nvme smartdata [HDD name] NVME S.M.A.R.T data. | |||
-tas info Gets TAS information. | |||
-tas pause Pauses a TAS service. | |||
-tas resume Resumes a TAS service. | |||
-tas refresh Triggers TAS to recollect data. | |||
-tas clear Clears collected TAS data in BMC. | |||
-tas period <sec> Sets the time length of a TAS update <limit 5 to 60 | |||
sec>. | |||
-tas exec <cmd> Executes a user's specified command. | |||
-tp info Gets MCU information. | |||
-tp info <type> Gets information of MCU type. (type: 1 - 3) | |||
-tp nodeid Gets a node ID. | |||
-summary Displays FW and BIOS information. | |||
-hostname [value] Gets/Sets a host name. | |||
-dcmi cap Lists information of DCMI capabilities. | |||
-dcmi power Gets the DCMI power readings. | |||
-dcmi ctl [value] Gets/Sets the DCMI management controller ID string. | |||
-mel list Shows BMC maintenance event log. | |||
-mel download <file> Downloads a BMC maintenance event log to a file. | |||
-mel clear Clears a BMC maintenance event log. | |||
-addrptl [option] Gets/Sets IP address protocol. | |||
option: 1 | IPv4 | |||
option: 2 | IPv6 | |||
option: 3 | Dual | |||
-lockdown [option] Checks the system's status mode or puts the system | |||
in lockdown mode. | |||
option: on | Lock | |||
option:off | Unlock | |||
</pre> | |||
== keywords == |
Revision as of 08:40, 10 August 2024
choco
choco install ipmicfg
Get IPMI Configuration
Show IPv4 Address and MAC
-m # Shows IPv4 address and MAC.
ipmicfg-win.exe -m
Help Options
IPMICFG Version 1.32.0 (Build 200910) Copyright(c) 2020 Super Micro Computer, Inc. Usage: IPMICFG params (Example: IPMICFG -m 192.168.1.123) -help Display a list of commands -m Shows IPv4 address and MAC. -m <ip> Sets IPv4 address (format: ###.###.###.###). -a <mac> Sets MAC (format: ##:##:##:##:##:##). -k Shows Subnet Mask. -k <mask> Sets Subnet Mask (format: ###.###.###.###). -dhcp Gets the DHCP status. -dhcp on Enables the DHCP. -dhcp off Disables the DHCP. -g Shows a Gateway IP. -g <gateway> Sets a Gateway IP (format: ###.###.###.###). -garp on Enables the Gratuitous ARP. -garp off Disables the Gratuitous ARP. -r Performs a BMC cold reset. Detects if a BMC reset was successfully performed on the IPMI device, use -d after -r. -fd <option> Resets to the factory defaults without preserving configurations. option: 1 | Preserves User configurations option: 2 | Restores to factory default and default password option: 3 | Sets user defaults to ADMIN/ADMIN -fdl Resets IPMI to the factory default. (Clean LAN). -fde Resets IPMI to the factory default. (Clean FRU & LAN). -d Detects if a BMC reset was successfully performed on the IPMI device. Note that this option can be only used after -r, -fd, -fdl or -fde -ver Gets firmware revision. -vlan Gets VLAN status. -vlan on [VLAN tag] Enables the VLAN and sets the VLAN tag. If VLAN tag is not given, it uses the previously saved value. -vlan off Disables the VLAN. -selftest Checks and reports the basic health status of the BMC. -raw Sends a RAW IPMI request and prints a response. Format: NetFn/LUN Cmd [Data1 ... DataN] -fru info Shows information of the FRU inventory area. -fru list Shows all FRU values. -fru cthelp Shows chassis type code. -fru help Shows help of FRU Write. -fru <field> Shows FRU field value. -fru <field> <value> Writes FRU. -fru backup <file> Backs up FRU to a file <Binary format>. -fru restore <file> Restores FRU from a file <Binary format>. -fru tbackup <file> Backs up FRU to a file <Text format>. -fru trestore <file> Restores FRU from a file <Text format>. -fru ver <v1> <v2> Gets/Sets the FRU version. (<v1> and <v2> are BCD-format) -sel info Shows SEL information. -sel list Shows SEL records. -sel del Deletes all SEL records. -sel raw Shows SEL raw data. -sdr [full] Shows SDR records and readings. -sdr del <sdr id> Deletes the SDR record. -sdr ver <v1> <v2> Gets/Sets the SDR version. (<v1> and <v2> are BCD-format) -nm nmsdr Displays NM SDR. -nm seltime Gets SEL time. -nm deviceid Gets the ID of the ME device. -nm reset Reboots ME. -nm reset2default Forces ME to reset to default settings. -nm updatemode Forces ME to enter the update mode. -nm selftest Gets self-test results. -nm listimagesinfo Lists ME information of images. -nm oemgetpower OEM Power command for ME. -nm oemgettemp OEM Temp. command for ME. -nm pstate Gets the maximum allowed CPU P-State. -nm tstate Gets the maximum allowed CPU T-State. -nm cpumemtemp Gets CPU/memory temperature. -nm hostcpudata Gets the host CPU data. -fan Gets the fan mode. -fan <mode> Sets the fan mode. -pminfo [full] Displays PMBus health information of power supply. -psfruinfo Displays FRU health information of power supply. -psbbpinfo Displays status of the backup battery. -autodischarge <module> Sets auto discharge by days. <day> -discharge <module> Manually discharges a battery. -user list Lists user privileges. -user help Shows a user privilege code. -user add <user id> <name> Adds a user. <password> <privilege> -user del <user id> Deletes users. -user level <user id> Updates user privileges. <privilege> -user setpwd <user id> Updates a user password. <password> -conf download <file> Downloads IPMI configuration to a binary file. -conf upload <file> Uploads IPMI configuration from a binary file. <option> option: -p | Bypass warning message -conf tdownload <file> Downloads IPMI configuration to a text file. -conf tupload <file> Uploads IPMI configuration from a text file. <option> option: -p | Bypass warning message -clrint Clears chassis intrusion. -reset <index> Resets system and forces to boot from the selected device. -soft <index> Initiates a soft-shutdown for OS and forces system to boot from the selected device. -ipv6 mode Shows the IPv6 mode. -ipv6 mode <mode> Sets the IPv6 mode. -ipv6 autoconfig Shows IPv6 auto configuration. -ipv6 autoconfig on Enables IPv6 auto configuration. -ipv6 autoconfig off Disables IPv6 auto configuration. -ipv6 list Lists IPv6 static and dynamic addresses. -ipv6 duid Shows IPv6 DUID. -ipv6 dns [ip] Gets/Sets IPv6 DNS server. -ipv6 add <id> <ip> Adds IPv6 static address. <prefix> -ipv6 remove <id> Removes IPv6 static address. -ipv6 route Displays IPv6 static route. -ipv6 route on Enables IPv6 static route. -ipv6 route off Disables IPv6 static route. -ipv6 route list Lists IPv6 static router information. -ipv6 route <id> <prefix Sets IPv6 static router information. value> <prefix length> <ip> -ipv6 route clear <id> Clears IPv6 static router information. -nvme list Displays the existing NVME SSD list. -nvme info Displays NVME SSD information. -nvme rescan Rescans all devices by in-band. -nvme insert <aoc> <group> Inserts SSD by out-of-band. <slot> -nvme locate <HDD name> Locates SSD. (in-band) -nvme locate <aoc> <group> Locates SSD. (out-of-band) <slot> -nvme stoplocate <HDD Stops locateing SSD. (in-band) name> -nvme stoplocate <aoc> Stops locateing SSD. (out-of-band) <group> <slot> -nvme remove <HDD name> Removes NVME device. (in-band) [option1] [option2] option1: 0 | Do eject after remove (Default) option1: 1 | Do not eject after remove option2:-p | Bypass warning message -nvme remove <aoc> <group> Removes NVME device. (out-of-band) <slot> [option] option: -p | Bypass warning message -nvme smartdata [HDD name] NVME S.M.A.R.T data. -tas info Gets TAS information. -tas pause Pauses a TAS service. -tas resume Resumes a TAS service. -tas refresh Triggers TAS to recollect data. -tas clear Clears collected TAS data in BMC. -tas period <sec> Sets the time length of a TAS update <limit 5 to 60 sec>. -tas exec <cmd> Executes a user's specified command. -tp info Gets MCU information. -tp info <type> Gets information of MCU type. (type: 1 - 3) -tp nodeid Gets a node ID. -summary Displays FW and BIOS information. -hostname [value] Gets/Sets a host name. -dcmi cap Lists information of DCMI capabilities. -dcmi power Gets the DCMI power readings. -dcmi ctl [value] Gets/Sets the DCMI management controller ID string. -mel list Shows BMC maintenance event log. -mel download <file> Downloads a BMC maintenance event log to a file. -mel clear Clears a BMC maintenance event log. -addrptl [option] Gets/Sets IP address protocol. option: 1 | IPv4 option: 2 | IPv6 option: 3 | Dual -lockdown [option] Checks the system's status mode or puts the system in lockdown mode. option: on | Lock option:off | Unlock